Send Message

KeLing Purification Technology Company Limited 

   -------------------------------------------------------------

             Advanced. High-Qulity. Reasonable.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home News

Six common reasons for not blowing of air shower

Certification
China KeLing Purification Technology Company certification
China KeLing Purification Technology Company certification
Customer Reviews
Keling had successfully supplied us following products on 25 Oct.2017 against PO NO.M170807; Their supplied Air Filters have been working satisfactorily since installation.We are satisfied with their products.

—— SIMPOR PHARMA

Since we do coopertae with them, they always offer good quality and keep the delivery on time to us, we do appreicated for their kind support !

—— Nasir

This is to certify that we bought U type air shower tunnel, Air Shower and HEPA filter, Secondary air filter ,perfilter for our project from KeLing Purification Technology Co. Ltd, 3C01 Tian Feng Commerce Square, Mid Building, No. 133, Baiyun AV, Baiyun Disctrict , Guangzhou , GuangDong, China against Contract No: 2014/4119005942 in October 22, 201

—— IATEC,Argentina

Product arrived faster than expected and they sent something special in addition to what I ordered. Nice people and fast service!

—— Mohammed Saad

I'm Online Chat Now
Company News
Six common reasons for not blowing of air shower
Latest company news about Six common reasons for not blowing of air shower

latest company news about Six common reasons for not blowing of air shower  0

Six common reasons for not blowing of air shower booth

 

The factory that uses the air shower sometimes will encounter the air shower room does not blow the phenomenon. When the air shower manufacturer fails to arrive in time to deal with the trouble on the spot, may refer to the following note to check the reason of air shower not blow:

 

1. First check whether the power supply switch and the emergency stop switch are on, if both reasons are not, check the circuit, whether the leakage switch is closed.

2. Whether the IC circuit board is configured to fuse the FUSE safety pipe, and if the fuse fuse is broken, the 4A should be replaced.

3. Check whether the fretting and optoelectronic switches are active, and if not, replace the fretting and optoelectronic switches.

4. If the AC contactor does not work, it will affect the blowing, need to replace the AC contactor.

5. If the circuit board can not output signal to AC contactor coil, it needs to replace IC circuit board.

6. No forced opening is allowed when the shower room is blowing. In case of emergency, stop by emergency switch.

Pub Time : 2022-10-13 17:33:18 >> News list